The short version of mobile phase fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2026-06-01 and is reviewed periodically as new material appears.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
| Parameter | Typical acceptance criterion | Notes |
|---|---|---|
| Resolution | ≥ 1.5 | Baseline separation of adjacent peaks |
| Tailing factor | ≤ 2.0 | Peak symmetry measure |
| Theoretical plates | > 2000 | Column efficiency indicator |
| Injection repeatability | ≤ 2% RSD | Relative standard deviation for replicate injections |
| Linearity | r² ≥ 0.995 | Calibration curve over the working range |
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Osmotic stress is defined as difficulty maintaining proper fluids in the cell within a hypertonic or hypotonic environment. MAAs accumulate within a cell's cytoplasm and contribute to the osmotic pressure within a cell, thus relieving pressure from salt stress in a hypertonic environment. As evidence of this, MAAs are seldom found in large quantities in cyanobacteria living in freshwater environments. However, in saline and hypertonic environments, cyanobacteria often contain high concentrations of MAAs. The same phenomenon was noted for some halotolerant fungi. But, the concentration of MAAs within cyanobacteria living in hyper-saline environments is far from the amount required to balance the salinity. Therefore, additional osmotic solutes must be present as well.
Absolute bioavailability compares the bioavailability of the active drug in systemic circulation following non-intravenous administration (i.e., after oral, buccal, ocular, nasal, rectal, transdermal, subcutaneous, or sublingual administration), with the bioavailability of the same drug following intravenous administration. It is the fraction of exposure to a drug (AUC) through non-intravenous administration compared with the corresponding intravenous administration of the same drug. The comparison must be dose normalized (e.g., account for different doses or varying weights of the subjects); consequently, the amount absorbed is corrected by dividing the corresponding dose administered. In pharmacology, in order to determine absolute bioavailability of a drug, a pharmacokinetic study must be done to obtain a plasma drug concentration vs time plot for the drug after both intravenous (iv) and extravascular (non-intravenous, i.e., oral) administration. The absolute bioavailability is the dose-corrected area under curve (AUC) non-intravenous divided by AUC intravenous. The formula for calculating the absolute bioavailability, F, of a drug administered orally (po) is given below (where D is dose administered).
By continuously scanning a surface, such as tissue section, nano-DESI can be used for imaging. By carefully choosing the experimental conditions, such as the nano-DESI solvent, additives, and the ionization mode (positive or negative) we can map the distribution of a wide variety of complex molecules on different surfaces. A few examples to mention are proteins, lipids, small metabolites, drugs or even the distribution of endogenous alkali metals. Nano-DESI has been applied for localized analysis of complex molecules and imaging of tissue sections, microbial communities and environmental samples. By decreasing the inner diameter of the primary and secondary capillaries, spatial resolution can be decreased to 20x20 μm or even smaller facilitating the analysis of individual cells. This way even various proteoforms can be measured in single cells as well as global and spatial metabolomics.
Lectin affinity chromatography is a form of affinity chromatography where lectins are used to separate components within the sample. Lectins, such as concanavalin A are proteins which can bind specific alpha-D-mannose and alpha-D-glucose carbohydrate molecules. Some common carbohydrate molecules that is used in lectin affinity chromatography are Con A-Sepharose and WGA-agarose. Another example of a lectin is wheat germ agglutinin which binds D-N-acetyl-glucosamine. The most common application is to separate glycoproteins from non-glycosylated proteins, or one glycoform from another glycoform. Although there are various ways to perform lectin affinity chromatography, the goal is extract a sugar ligand of the desired protein.
Sources: en.wikipedia.org
Originally, seven such proteins were discovered. Of these, six (BMP2 through BMP7) belong to the Transforming growth factor beta superfamily of proteins. BMP1 is a metalloprotease. Since then, thirteen more BMPs, all of which are in the TGF-beta family, have been discovered, bringing the total to twenty. The current nomenclature only recognizes 13, as many others are put under the growth differentiation factor naming instead.
The mechanism of the magnetic levitation model in 3D cell culturing combines various techniques within the frame of nanobiotechnology. One approach to the process is described below. At the beginning of the process, magnetite nanoparticles are added, then dispersed uniformly throughout the cell culture. After the cell culture containing the nanoparticles has been allowed to incubate, it is moved to a petri dish, and a magnetic drive is placed on top of the petri dish. When an external magnetic field is applied through the drive, it causes the cell culture mixture, still containing the magnetic nanoparticles, to levitate within the petri dish. The levitation results in immediate cell-cell interaction. After the mixture disperses and stretches, there is gradual formation of 3D structures that are visible after about 4 hours. The magnetic iron oxide nanoparticles are described as the "nanoshuttle", in which their magnetic properties allows the cells to rise within the culture they are added to due to the external magnetic field, thus "shuttling".
Color markers are sometimes added to loading dyes for gel electrophoresis in the separation of DNA fragments. Loading dyes keep DNA samples below the surface of the agarose gel, and the color markers within help keep track of the migration front of the DNA as it moves along the gel. For PAGE, some commercially available molecular weight markers (also called "ladders" because they look like the rungs of a ladder after separation) contain pre-stained proteins of different colours, so it is possible to determine more accurately where the proteins of interest in the samples might be.
In 2004, a group of ACS members criticized the compensation of former executive director and chief executive officer John Crum, whose total salary, expenses, and bonuses for 2002 was reported to be $767,834. The ACS defended the figure, saying that it was in line with that of comparable organizations, including for-profit publishers. As of 2016, two employees were reported to have a total compensation exceeding $900,000, while 694 had a compensation exceeding $100,000. Reagent Chemicals (Reagent ACS), standards of chemical purity ACS style, the ACS's citation standard Association for Learned and Professional Society Publishers Chemical Abstracts Service List of learned societies List of international professional associations National Chemistry Week National Historic Chemical Landmarks
Uniform and genetically stable cultivars can be inadequate for dealing with environmental fluctuations and novel stress factors. Plant breeders have focused on identifying crops which will ensure crops perform under these conditions; a way to achieve this is finding strains of the crop that is resistance to drought conditions with low nitrogen. It is evident from this that plant breeding is vital for future agriculture to survive as it enables farmers to produce stress resistant crops hence improving food security. In countries that experience harsh winters such as Iceland, Germany and further east in Europe, plant breeders are involved in breeding for tolerance to frost, continuous snow-cover, frost-drought (desiccation from wind and solar radiation under frost) and high moisture levels in soil in winter. Breeding is not a quick process, which is especially important when breeding to ameliorate a disease. The average time from human recognition of a new fungal disease threat to the release of a resistant crop for that pathogen is at least twelve years.
Sources: en.wikipedia.org
AST is similar to alanine transaminase (ALT) in that both enzymes are associated with liver parenchymal cells. The difference is that ALT is found predominantly in the liver, with clinically negligible quantities found in the kidneys, heart, and skeletal muscle, while AST is found in the liver, heart (cardiac muscle), skeletal muscle, kidneys, brain, and red blood cells. As a result, ALT is a more specific indicator of liver inflammation than AST, as AST may be elevated also in diseases affecting other organs, such as myocardial infarction, acute pancreatitis, acute hemolytic anemia, severe burns, acute renal disease, musculoskeletal diseases, and trauma. The elevated AST level in hemorrhagic fever caused by crimean-congo hemorrhagic fever virus is associated with high mortality rate. AST was defined as a biochemical marker for the diagnosis of acute myocardial infarction in 1954. However, the use of AST for such a diagnosis is now redundant and has been superseded by the cardiac troponins. Laboratory tests should always be interpreted using the reference range from the laboratory that performed the test. Example reference ranges are shown below:
The BtuCD and HI1470/1 are classified as large (Type II) ABC importers. The transmembrane subunit of the vitamin B12 importer, BtuCD, contains 10 TM helices and the functional unit consists of two copies each of the nucleotide binding domain (NBD) and transmembrane domain (TMD). The TMD and NBD interact with one another via the cytoplasmic loop between two TM helices and the Q loop in the ABC. In the absence of nucleotide, the two ABC domains are folded and the dimer interface is open. A comparison of the structures with (BtuCDF) and without (BtuCD) binding protein reveals that BtuCD has an opening that faces the periplasm whereas in BtuCDF, the outward-facing conformation is closed to both sides of the membrane. The structures of BtuCD and the BtuCD homolog, HI1470/1, represent two different conformational states of an ABC transporter. The predicted translocation pathway in BtuCD is open to the periplasm and closed at the cytoplasmic side of the membrane while that of HI1470/1 faces the opposite direction and open only to the cytoplasm. The difference in the structures is a 9° twist of one TM subunit relative to the other.
The therapeutic index (TI) is used to quantify the risks and benefits of a certain drug. It describes the relationship between toxic dose and minimum effective dose, thus providing an important insight into the safety of a drug. The Therapeutic Index is calculated using the following equation: TI = TD50 / ED50, where TD50 is the dose at which toxicity presents in 50% of the population, and ED50 is the dose needed to produce 50% of maximal response. From the equation, a high TI indicates that the drug needs a high dose to induce toxicity in 50% of the population or a low dose to achieve the minimum effective dose, and vice versa. In the case of physiological antagonists, for example, insulin has a narrow TI. A narrow TI indicates that either excess or lack of insulin can cause significant risks. On one hand, lack of insulin may result in high blood glucose levels and kidney or cardiovascular damage. On the other hand, excess insulin may result in insulin-induced hypoglycemia as aforementioned. Another example is dimercaprol, a chemical antagonist in treating metal toxicity. Dimercaprol has a narrow TI so it is replaced by its derivative, 2,3-dimercaptosuccinic acid (DMSA).
Originally, seven such proteins were discovered. Of these, six (BMP2 through BMP7) belong to the Transforming growth factor beta superfamily of proteins. BMP1 is a metalloprotease. Since then, thirteen more BMPs, all of which are in the TGF-beta family, have been discovered, bringing the total to twenty. The current nomenclature only recognizes 13, as many others are put under the growth differentiation factor naming instead.
During barcode sequencing, high molecular weight DNA samples that contain the targeted DNA sequence, ranging from fifty to several hundred kilobases in size, are combined with gel beads containing unique barcodes, enzymes, and sequencing reagents. Microfluidic device can partition input DNA molecules into individual nanoliter-sized droplets of water-in-oil emulsion, called GEMs. Each GEM contains gel beads coated with the same barcode and primers, and a small amount of DNA. The primers are complementary to specific regions of the DNA molecule, allowing for amplification of the DNA in the droplets through PCR. The barcodes enable the identification and grouping of sequencing reads that originate from the same long fragment, which is crucial for downstream analysis.
Sources: en.wikipedia.org
Method validation is the documented process of confirming that an HPLC procedure is suitable for its intended use. It evaluates accuracy, precision, specificity, linearity, range, detection limits, and robustness. Validation criteria depend on the regulatory context and the sample type.
System suitability tests are short checks performed before or during an HPLC run to verify instrument and method performance. They often include resolution, tailing factor, theoretical plates, and injection precision. Results must meet predefined limits for sample data to be accepted.
HPLC retention time alone cannot definitively identify an unknown substance. A match with a reference standard under identical conditions provides supporting evidence. Confirmation typically requires mass spectrometry, nuclear magnetic resonance, or another orthogonal technique.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.